| Boiler Size No. | 80 | 100 | 125 | 150 | 175 | 200 | 250 | 300 | 350 | 400 | 500 | 600 | ||
| Heating Surface (Fire Side) |
Sq. ft. m2 |
400 38 |
500 47 |
625 58 |
750 71 |
900 85 |
1000 94 |
1250 117 |
1500 140 |
1750 164 |
2000 188 |
2500 235 |
3000 280 |
|
| Heating Surface (Water Side) |
Sq. ft. m2 |
448 42 |
546 51 |
682 64 |
831 77 |
995 93 |
1102 103 |
1375 128 |
1633 152 |
1919 178 |
2199 204 |
2748 255 |
3281 305 |
|
| Steam Output From & AT 212 deg. (100 deg C) |
Ibs./hr Kg/hr |
2760 1252 |
3450 1565 |
4312 1955 |
5175 2347 |
6037 2738 |
6900 3129 |
8625 3912 |
10350 4694 |
12075 5476 |
13800 6258 |
17250 7823 |
20700 9388 |
|
| Radiation | Sq. ft. Steam EDR m2 Steam EDR |
11200 1045 |
14000 1300 |
17500 1625 |
21000 1950 |
24500 2276 |
28000 2601 |
35000 3252 |
42000 3902 |
49000 4552 |
56000 5202 |
70000 6503 |
84000 7804 |
|
| Radiation | Sq. ft. Water EDR m2 Water EDR |
17850 1658 |
22400 2081 |
28000 2601 |
33600 3121 |
39200 3642 |
44800 4162 |
56000 5202 |
67200 6243 |
78750 7316 |
89600 8324 |
112000 10405 |
134400 12486 |
|
| MBH KCAL per Hr. |
1000 |
2678 675 |
3348 843 |
4184 1054 |
5021 1265 |
5858 1476 |
6695 1687 |
8369 2108 |
10042 2530 |
11716 2952 |
13390 3374 |
16738 4217 |
20085 5060 |
|
| Gas Burner | BTU Input 1000 Kcal Input 1000 |
3360 846 |
4200 1058 |
5250 1323 |
6300 1587 |
7350 1847 |
8400 2116 |
10500 2246 |
12600 3175 |
14700 3704 |
16800 4233 |
21000 5292 |
25200 6350 |
Motor Fan | 3450 RPM HP | 2 | 2 | 2 | 3 | 3 | 3 | 3 | 5 | 5 | 5 | 7 1/2 | 15 |
| Gas Pressure Max. Inlet To Reg. |
psi/hr Kg/Cm2 |
1 0.1 |
1 0.1 |
30 0.7 |
30 0.7 |
30 0.7 |
30 4.2 |
30 4.2 |
30 4.2 |
30 4.2 |
30 4.2 |
30 4.2 |
30 4.2 |
Gas Pressure Manifold |
IN W.C. mm W.C. |
7 127 |
7 127 |
7 127 |
7 178 |
7 178 |
7 229 |
8 229 |
9 254 |
9 254 |
13 280 |
13 330 |
19 330 |
Oil Burner (No. 2 Oil)* |
GPH IPH |
24 91 |
30 114 |
37.5 142 |
45 170.5 |
52.5 198 |
60 227 |
75 284 |
90 341 |
105 397.5 |
120 454 |
150 568 |
180 681.5 |
A | Diameter of Insulated Boiler |
IN cm |
59 150 |
59 150 |
65 165 |
71 180 |
71 180 |
77 196 |
77 196 |
83 211 |
89 226 |
96 241 |
96 241 |
102 257 |
| B | Length Of Boiler |
IN cm |
124 315 |
145 368 |
150 381 |
149 378 |
172 437 |
168 427 |
198 510 |
213 541 |
213 541 |
207 526 |
253 643 |
260 660 |
| C | Length With W&D Burner Overall |
IN cm |
154 391 |
175 445 |
178 452 |
177 450 |
200 508 |
206 523 |
237 602 |
249 632 |
249 632 |
243 617 |
294 747 |
300 762 |
| D | Width With Controls And/Or "B" System |
IN cm |
70 178 |
70 178 |
76 193 |
82 208 |
82 208 |
88 224 |
88 224 |
94 239 |
100 254 |
106 269 |
106 269 |
112 285 |
| E | Height (Stack To Floor) |
IN cm |
76 198 |
76 198 |
82 216 |
88 231 |
88 231 |
94 249 |
94 249 |
100 264 |
106 280 |
112 295 |
112 300 |
120 320 |
| F | Length Of Skids |
IN cm |
141 358 |
162 412 |
159 409 |
162 412 |
195 495 |
181 460 |
212 539 |
225 572 |
225 572 |
217 551 |
268 681 |
276 701 |
| G | Width Of Skids |
IN cm |
53 135 |
53 135 |
59 150 |
65 163 |
65 163 |
70 178 |
70 178 |
77 196 |
83 211 |
89 226 |
89 226 |
95 241 |
| H | Size Steam Outlet | 15 psi IN 1.05 Kg/cm2 mm 150 psi IN 10.5 Kg/cm2 mm |
6 152 2 51 |
8 203 2 1/2 64 |
8 203 3 76 |
8 203 3 76 |
8 203 4 102 |
8 203 4 102 |
8 203 4 102 |
10 254 6 152 |
10 254 6 152 |
10 254 6 152 |
12 305 8 203 |
12 305 8 203 |
| J | Location Of Steam Outlet |
IN cm |
57 144 |
69 175 |
69 175 |
72 183 |
82 208 |
75 191 |
84 213 |
111 282 |
110 274 |
110 274 |
133 338 |
136 345 |
| K | Size Relief Valve Opening | As Required By Code | ||||||||||||
| * Oil Pump Motors: (1/2 HP thru Size 150, 1 1/2 HP thru Size 350, 2 HP thru Size 600.) | ||||||||||||||
![]() |
![]() |