Boiler Model DIM. 156 205 253 304 353 402 508 625 751 1024 1276 1506 1758 2007 2506 3004 3502 3753 4005 4502 5000 Boiler Model
Lengths:
Overall
Shell
Base
Front Plate To
Skid Extension
Rear Plate To
Center Line Of Stack
Front Of Base To
End Of Burner (IC Only)
Front Plate To
Nozzle

A
B
C

D

E

F

G

114
81
88

24

2

17

27

136
103
107

24

2

17

34 1/2

139
105
109

24

2

14

38

157
123
128

24

2

13

42

144
108
110

26

3 1/2

12

41

156
120
118

26

3 1/2

15

43

182
146
149

26

3 1/2

15

43

176
136
134

28

2

13

47

199
159
158

28

2

13

47

186
143
143

30

2

21

48

215
172
170

30

2

21

48

238
190
190

34

2

18

55

264
217
217

34

2

18

55

236
187
185

36

2

19

70

275
227
226

36

2

24

70

277
228
228

36

2

27

73

286
238
233

36

2

26

60

283
235
234

36

2

-

73

301
248
251

40

2

-

73

337
275
287

49

2

-

73

364
302
314

49

2

-

73
Lengths:
Overall
Shell
Base
Front Plate To
Skid Extension
Rear Plate To
Center Line Of Stack
Front Of Base To
End Of Burner (IC Only)
Front Plate To
Nozzle
Widths:
Overall
Centerline To
Lagging
Centerline TO
Water Column
Over Jacket
Base Width Inside
Base Width Inside

H

I

J
K
L
M

61

27

34
54
38
30

61

27

34
54
38
30

65

29

36
58
40
32

65

29

36
58
40
32

72

33

39
66
50
42

72

33

39
66
50
42

72

33

39
66
50
42

80

36 1/2

44
73
50 1/2
42 1/2

80

36 1/2

44
73
50 1/2
42 1/2

89

41 1/2

48
83
65 1/2
57 1/2

89

41 1/2

48
83
65 1/2
57 1/2

95

44 1/2

51
89
70 1/2
62

107

44 1/2

51
89
70 1/2
62 1/2

107

50

57
100
80
72

114

50

57
100
80
72

122

53

61
106
87
79

128

57

65
114
87
77

128

61

67
122
87
77

128

61

67
122
87
77

128

61

67
122
87
77

95

61

67
122
87
77
Widths:
Overall
Centerline To
Lagging
Centerline TO
Water Column
Over Jacket
Base Width Inside
Base Width Inside
Heights:
Overall
Base To Vent Outlet
Base To Lagging
Height Of Runner

N
O
P
Q

73
71
12
6

73
71
12
6

76
73
12
6

76
73
12
6

85
81 1/2
12
6

85
81 1/2
12
6

85
81 1/2
12
6

92 1/2
92
12
6

92 1/2
92
12
6

102
101 1/2
12
6

102
101 1/2
12
8

110
110
12
8

110
110
12
8

120
120
12
8

120
120
12
12 5/16

127
127
12
12 5/16

135
135
12
12

147
143
12
12

147
143
12
12

147
143
12
12

147
143
12
12
Heights:
Overall
Base To Vent Outlet
Base To Lagging
Height Of Runner
Connections:
Feedwater - Right/Left
Auxiliary Conn. - Right/Top
Surface Blowoff - Right
Auxiliary Conn. - Top
Stack Conn. O.D.
High Pressure:
Steam Nozzle
Blowdown Front
Blowdown Rear
Low Pressure:
Steam Nozzle
Blowdown Front
Blowdown Rear

R
S
T
U
V

W
X
Y

W
X
Y

1
1
1 1/2
1 1/2
9 7/8

2
-
1

4
-
1

1
1
1 1/2
1 1/2
9 7/8

2
-
1

4
-
1 1/4

1
1
1 1/2
1 1/2
11 7/8

2
-
1

4
-
1 1/4

1
1
1 1/2
1 1/2
11 7/8

2
-
1

4
-
1 1/4

1 1/4
1
1 1/2
1 1/2
15 7/8

3
-
1 1/4

6 *
-
1 1/2

1 1/4
1
1 1/2
1 1/2
15 7/8

3
-
1 1/4

6 *
-
1 1/2

1 1/4
1
1 1/2
1 1/2
15 7/8

4 **
-
1 1/4

6 *
-
1 1/2

1 1/4
1
2
2
17 7/8

4 **
-
1 1/4

6 *
-
1 1/2

1 1/4
1
2
2
17 7/8

4 **
-
1 1/4

6 *
-
2

2
1
2
2
19 7/8

6 **
1 1/4
1 1/4

8 *
2
2

2
1
2
2
19 7/8

6 **
1 1/4
1 1/4

8 *
2
2

2
1
2
2
23 7/8

6 **
1 1/2
1 1/2

10 *
2
2

2
1
2
2
23 7/8

6 **
1 1/2
1 1/2

10 *
2
2

2
1
2
2
23 7/8

6 **
1 1/2
1 1/2

12 *
2
2

2 1/2
1
2
2
23 7/8

8 **
1 1/2
1 1/2

12 *
2
2

2 1/2
1
2
2
25 7/8

8 **
1 1/2
1 1/2

12 *
2
2

2 1/2
1
2
2
25 7/8

8 **
2
2

12 *
2
2

2 1/2
1
2
2
25 7/8

8 **
2
2

12 *
2
2

2 1/2
1
2
2
25 7/8

8 **
2
2

12 *
2
2

2 1/2
1
2
2
25 7/8

8 **
2
2

12 *
2
2

2 1/2
1
2
2
25 7/8

8 **
2
2

12 *
2
2
Connections:
Feedwater - Right/Left
Auxiliary Conn. - Right/Top
Surface Blowoff - Right
Auxiliary Conn. - Top
Stack Conn. O.D.
High Pressure:
Steam Nozzle
Blowdown Front
Blowdown Rear
Low Pressure:
Steam Nozzle
Blowdown Front
Blowdown Rear
Access Openings:
Handholes
High Pressure
Low Pressure
Manway 12x16"
High Pressure
Low Pressure
Z


ZZ



5
5

-
-


5
5

-
-


4
5

1
-


4
5

1
-


4
5

1
-


4
5

1
-


4
5

1
-


4
4

1
1


4
4

1
1


4
4

1
1


4
4

1
1


4
4

1
1


4
4

1
1


4
4

1
1


4
4

1
1


4
4

1
1


4
4

1
1


4
4

1
1


4
4

1
1


4
4

1
1


4
4

1
1
Access Openings:
Handholes
High Pressure
Low Pressure
Manway 12x16"
High Pressure
Low Pressure
Minimum Clearances:
Tube Clearance Front
Tube Clearance Rear
Rear Door Swing Rear
Rear Door Swing Side (Max.)

TF
TR
DR
DS

59
59
33
62

81
81
33
62

80
80
35
66

98 1/2
98 1/2
35
66

74
74
39
74

86
86
39
74

112
112
39
74

102
102
44
85

125
125
44
85

106 1/2
106 1/2
49
94

135 1/2
135 1/2
49
94

147 1/2
147 1/2
52
99

174 1/2
174 1/2
52
99

144 1/2
144 1/2
57
110

184
184
57
110

182
182
61
117

192
192
69
129

189
189
69
129

202
202
69
129

226
226
69
129

256
256
69
129
Minimum Clearances:
Tube Clearance Front
Tube Clearance Rear
Rear Door Swing Rear
Rear Door Swing Side (Max.)
Minimum Boiler Room Length Allowing For Door Swing And Tube Removal Dimensions BR/DW Include 3'-0" Clearance At Front of Boiler
Front of Boiler
Rear of Boiler
Thru Door or Window
BF
BR
DW
172 1/2
199 1/2
174
216 1/2
243 1/2
196
219 1/2
244 1/2
200
256 1/2
281 1/2
218
220 1/2
243 1/2
209
244 1/2
267 1/2
221
296 1/2
319 1/2
247
281 1/2
301 1/2
244
327 1/2
347 1/2
267
298 1/2
315 1/2
258
356 1/2
373 1/2
287
389 1/2
407 1/2
312
443 1/2
461 1/2
339
388 1/2
403 1/2
316
467 1/2
482 1/2
356
470 1/2
481 1/2
361
498 1/2
501 1/2
379
492 1/2
495 1/2
376
518 1/2
525 1/2
393
569 1/2
588 1/2
429
626 1/2
642 1/2
456
Front of Boiler
Rear of Boiler
Thru Door or Window
Boiler Model DIM. 156 205 253 304 353 402 508 625 751 1024 1276 1506 1758 2007 2506 3004 3502 3753 4005 4502 5000 Boiler Model
Note * 150 PSIG RF Flange All Dimension are approximate & may be used for layout. Superior Boiler Works, Inc. reserves the right to change dimensions due to product revisions or job requirements. Note
** 300 PSIG RF Flange
Dimensional Data For Mohawk 3 Pass Dry Back Boilers, 30 Thru 1000 B.H.P, 15 & 150 lb. Design


To Top of Page