Mohawk boiler/burner units are covered by Superior's waranty effective for 18 months from shipment or one year from date of start-up. See warranty for complete details.
Davited front doors allow for total access to the return tubes without interference of baffles or inner doors.
To assure ease of opening and closing, front and rear doors utilize studs with lugs and brass nuts.
Customers have a choice of burner manufacturers to gain the most efficient operation. Standard burners are specifically matched with the pressure vessel for complete, efficient cobustion. Burners are available in either gas or oil, or in a combination of gas and oil using either air or pressure atomization of the oil.
Air louver linkage and setting visible for ease of mointoring adjustment and cleaning.
Control panel - burner, skid or boiler mounted for ease of installation and maintenance.
Control circuit junction box with terminal strip with skid or burner-mounted control panel to permit ease of checkout of individual controls.
Factory-installed gas train is equipped with main gas pressure regulator. Standard gas trains comply with UL requirements and can be modified to meet IRI, FM and other codes.
Structural steel skid-type base. Supports and protects burner.
Location of large diameter furnace in boottom third of the boiler proivides for complete combustion and maximum heat transfer while being in contact with coolest boiler water.
Furnaces for Section I (high pressure boilers) 24" diameter and larger are of Morison corrugation design.
Front/rear door gaskets are made of ceramic fiber for long life.
Roller-bearing supported davit makes possible a reduced opening space and can be arranged for left or right hand opening.
Two-inch mineral fiber insulation with 8-lb. density contivutes to jacket support and reduced sheel heat loss.
22-gauge galvanized/phosphate coated steel jacket is painted with a hard enamel finish.
Efficient/economical 3-pass design.
Front smokebox and doors are lined with ceramic fiber blanket.
Standard Features:
Units Designed and Fabricated To ASME Boiler and Pressure Vessel Code Requirements: Section IV - 15 psig. Section I - 150 psig.
Insulated with 2" - 8lb. Density Mineral Fiber Insulation.
Jacket Material 22 Gauge Galvanized - Phosphate Coated Steel.
Davited Doors: Front - 353 and Larger
Davited Doors: Rear - All Units
Rear Access Plug. 15" Dia. 353 Thru 3502
Rear Access Plug. 19" Dia. 3753 Thru 5000
Handholes: 3" x 4" Low Pressure (5) 156 Thru 508
Handholes: 3" x 4" Low Pressure (4) 625 Thru 5000
Handholes: 3" x 4" High Pressure (5)156 Thru 205
Handholes: 3" x 4" High Pressure (4) 253 Thru 5000
Manway: 12" x 16" Low Pressure (1) 625 Thru 5000
Manway: 12" x 16" High Pressure (1) 253 Thru 5000
Surface Blow Down Connection.
Standard Trim (Boiler)
ASME Safety Valve(s)
Water Column w/Water Level Gauge Glass, Try Cocks (As Req'd)
Low Water Cutoff / Pump Control, Blowdown Valve.
Operating Pressure Control.
High Limit Pressure Control (Manual Reset).
Firing Rate Control (Hi-Lo-Off or Modulating Firing Only)
Pressure Gauge w/Shutoff and Inspections Gauge Cocks.