| In Stock Items |
| Honeywell Part # |
Part Discription |
| 133568 |
V4055 Aux Switch |
| 198162EA |
Internal Transformer 120 Vac at 50/60 Hz for Modutrol IV motors |
| 220736B |
Internal Auxiliary Switch Kits: 2 Switches spdt for Modutrol IV motors are actuated by adjustable cams inside the motor. |
| 30112A |
Potentionmeter 135 OHMS Res for S443A |
| C645A 1022*** |
Air Pressure Switch: 3.0 to 21.0 inches H2O, Nat. or LP Gas or Air, Breaks on Fall |
| C645A 1030*** |
Air Pressure Switch: 3.0 to 21.0 inches H2O, Nat. or LP Gas or Air, Breaks on Fall |
| C645B 1013*** |
Air Pressure Switch: 3.0 to 21.0 inches H2O, Nat. or LP Gas or Air, Makes On Fall |
| C645D 1052*** |
Air Pressure Switch: 2.0 to 20.0 inches H2O, Air Auto Recycle, Breaks on Fall |
| C7015A 1118 |
Infrared (Lead Sulfide) Flame Detector for: infrared radiation from gas, oil, coal, or dual-fuel flames. |
| C7015A 1126 |
Infrared (Lead Sulfide) Flame Detector for: infrared radiation from gas, oil, coal, or dual-fuel flames. Use with: R7248A,B Amplifier and R4140 or BC7000; R4075C,D,E and R4138C,D relays; R7848A,B and 7800 Series Relay Modules or R7748B Amplifiers and BCS 7700; 104662D Photocell |
| C7027A 1023 |
Minipeeper Ultraviolet Flame Detector 0 to 215 Plus Degres F, 1/2" Female NPT Pipe MTG, 8' Leads |
| C7027A 1031 |
Minipeeper Ultraviolet Flame Detector, 1/2" Female NPT Pipe MTG, -40 to 215 Plus Degres F with 8'lead wire |
| C7027A 1049 |
Minipeeper Ultraviolet Flame Detector, 1/2" Female NPT Pipe MTG, 0 to 215 Plus Degres F with 8' lead wire |
| C7027A 1072 |
Minipeeper Ultraviolet Flame Detector, 1/2" Female NPT Pipe MTG, -40 to 215 Plus Degres F with 8'lead wire |
| L4006A 1017 |
Aquastat Controllers; Application = High or Low Limit, Switching Action = Contacts Break on Temp Rise, Operating Range = 100-240 Deg F, Differential Midscale = 5 to 30, adj., Includes 1 1/2" Insulation. |
| L4006E 1067 |
Aquastat Controllers: Application = High Limit, Switching Action = Contacts Break on Temp Rise, Operating Range = 130-270 Deg F, Differential Midscale = Manual Reset, Includes, 3" Insulation, stop factory set at 250 Def F; well adapter and heat-conductive compound. |
| L4008A 1015 |
Remote Bulb Controllers: Application = High or Low Limit, Switching Action = Contacts Break on Temp Rise, Operating Range = 100-240 Def F, Differential Midscale = 5-30 deg F adj., Includes 5 1/2' Capillary. |
| L4008E 1156 |
Remote Bulb Controllers; Application = High Limit, Switching Action = Contacts Break on Temp Rise, Operating Range = 130-270 Deg F, Differential Midscale = Manual Reset, Includes 5 1/2' Capillary; factory set stop at 250 deg f; heat conductive compound. |
| L404A 1354 |
Pressuretrol Controllers; Operating Range = 2 to 15 PSIG, Subtractive Differential (Differential @ Midscale)2-6 PSIG, Pressure Surge-25 PSIG, Type = SPST, Action on Pressure Rise = Breaks. |
| L404A 1396 |
Pressuretrol Controllers; Operating Range = 10 to 150 PSIG, Subtractive Differential 8 to 16 PSIG, Pressure Surge = 225PSIG, Type SPST, Action on Pressure Rise Breaks. |
| L404A 1404 |
Pressuretrol Controllers; Operating Range = 20 to 300 PSIG, Subtractive Differential 15 to 40 PSIG, Pressure Surge = 350 PSIG, Includes = Siphon Loop, Type = SPST, Action on Pressure Rise. |
| L404C 1147 |
Pressuretrol Controllers; Operating Range= 2 to 15 PSIG, Subtractive Differential = Manual Reset, Pressure Surge = 225 PSIG, Type = SPST, Action on Pressure Rise Breaks. |
| L404C 1162 |
Pressuretrol Controllers; Operating Range = 10 to 150 PSIG, Subtractive Differential = Manual Reset, Pressure Surge- 225 PSIG, Type = SPST, Action on Pressure Rise Breaks. |
| L404F 1102 |
Pressuretrol Controllers; Operating Range= 10 to 150 PSIG, Subtractive Differential 10-22 PSI Adj, Max DIAPH Pressure Surge = 225 PSIG, Type = SPST, MERCURY FREE |
| L6006A 1145 |
Aquastat Controllers; Application = Ciculator and High Limit or Low Limit, Switching Action = SPDT, Operating Range = 100 to 240 Deg F, Differential Midscale = 5 to 30 adj., Includes = 3" Insulation, stop factory set at 240 Deg F, well adapter and heat-conductive compound. |
| L6008A 1192 |
Remote Bulb Controllers; Application = Ciculator and Low Limit, Switching Action = SPDT, Operating Range = 100-240 Degree F, Differential Midscale = 5 to 30 adj., Includes = 5 1/2' Capillary, factory set stop at 240 Deg F, heat-conductive compound. |
| L604A 1185 |
Pressure Controls/Limits; Operating Range = 10 to 150 PSIG, Subtractive Differential (Differential at Midscale) = 8 to 16 PSIG, Pressure Surge = 225 PSIG, Pressure Surge = 225 PSIG Includes = Siphon Loop, Type = SPDT, Action on Pressure Rise- R-W Makes, R-B Breaks. |
| L604A 1193 |
Pressure Controls/Limits; (Phos-Bronze Bellows) Operarting Range- 20 to 300 PSIG, Subtractive Differential (Differential at Midscale) = 15 to 40 PSIG, Pressure Surge = 350 PSIG, Includes = Siphon Loop, Type-SPDT, Action on Pressure Rise = R-W Makes, R-B Breaks. |
| L91A 1136 |
Proportional Pressuretrol Controllers; Control Range = 10 to 300 PSIG, Pressure Surge Max = 325 PSIG, Differential (At Midscale) = 12 PSIG, Setting Means = Screw adj. top of case. |
| L91B 1050 |
Proportional Pressuretrol Controllers; (Pipe Connection: 1/4" NPT, Female Fitting (Can be mounted directly on siphon loop.) Control Range = 5 to 150 PSIG, Pressure Surge Max = 1151 PSIG, Differential (At Midscale) = 5 to 23 PSIG, Setting Means-Screw adj. Top Of Case. |
| M9174B 1027 |
Modutrol IV Motor; Power Supply = 120 Vac at 50/60 Hz, Timing-30 sec, Stroke (Degreses) = 90, Includes = 1 spdt auxiliary switch |
| M9174D 1007 |
Modutrol IV Motor; Power Supply = 24 VAC at 50/60 Hz, Timing-30 to 60 sec, Stroke (Degrees) = 90-160, Includes = 220738A Adapter bracket to match height of Mod III Motors., Comments = Shorter Timing applies to 90 degree stroke. |
| M9184D 1021 |
Modutrol IV Motor; Power Supply = 24 VAC at 50/60 HZ, Torque = 150 lb-in., Timing = 30 to 60, Stroke (Degrees) = 90 to 160, Includes = Tapped shaft; 220738A adapter bracket to match height of Mod III Motors. (PLEASE NOTE; Torque given is normal running torque. Breakaway torque rating is 2X normal running torque and is the maximum torque
available to overcome occasional large loads such as a seized damper or valve. MOTOR NOT TO BE USED CONTINUOUSLY AT BREAKAWAY TORQUE RATING.) |
| M9484E 1009 |
Modutrol IV Motor; Description = With 1 cam-adjusted Micro Switch spdt auxiliary switch and vibration-resistant electronic balancing circuit, Timing = 15.0 or 30.0 sec, Switch Auxiliary Differential = Factory set at 1 degree (selectable for 10 degrees)., Comments = with tapped shaft. |
| Q179A 1076 |
Flame Rectifier Gas Pilots; Application = For intermittent or interrupted ignition. Has both flame electrode and ignition electrode. |
| Q7800B 1003 |
Terminal Universal Wiring Subbase; Burner or wall mounting |
| R7247A 1005 |
Flame Safeguard Amplifier, Rectification, Green, Not Self Checking, 2 to 4 Second Flame Failure Response Time, Use with Gas |
| R7847A 1033 |
Flame Signal Amplifiers; Type = Rectifying Flame Rod Holder, Models = C7004, C7007, (C7011 See Instructions for Holder.), Complete Assemblies: C7008, C7009, Q179. |
| Flame Signal Amplifiers; Type = Photocell (Use Only Honeywell Photocell, Part No. 38316), Models = C7010, C7013, C7014 |
| R7848A 1008 |
Flame Signal Amplifiers; Type = Infrared (Lead Sulfide), Models = C7015 |
| R7849A 1023 |
Flame Signal Amplifiers; Type = Ultraviolet (Mini Peeper), Models = C7027, C7035, (C7044 For use with C7012A/C parallel detectors or flame rod applications with leadwire lengths greater than 50 feet.) |
| RM7840G 1022 |
Programmer; Automatic Control 120 Vac, 50/60 Hz with Dust Cover |
| RM7840L 1018 |
Programmer; Relay module without display; 50/60 HZ, Replaces = R4140L |
| RM7885A 1015 |
Semi-Automatic Primary Control; Replaces = R485 |
| RM7890A 1015 |
Primary Control; Automatic primary relay module, (Replaces = RA890F,G,H To replace RA890F, select R7847A Flame Signal Amplifier. To replace RA890G, select R7849A Flame Signal Amplifier, To replace RA890H, select R7847B Flame Signal Amplifier, Check timings for application requirements. |
| RM7895A 1014 |
Full Function Primary Control; Intermittent primary realy module without AFSC, Replaces = R7795A, B |
| RM7896C 1010 |
Full Function Primary Control; Interrupted pilot, 15 sec postpurge |
| S7800A 1001 |
Key Board Display Module; Use with = RM7800, RM7840, RM7895, RM7890, RM7885, RM7823 Relay Modules. |
| ST7800A 1039 |
Plug-In Purge Timer Card; 30 Seconds Prepurge Timing, Use with = RM7800; RM7840; RM7895; RM7838 Relay Modules. |
| ST7800 1054 |
Plug-In Purge Timer Card; 60 Seconds Prepurge Timing, Use with = RM7800; RM7840; RM7895; RM7838 Relay Modules. |
| T991A 1061 |
Proportional Temperature Controller; Temperature Ratings 160 deg F to 260 deg F, Throttling Range (Adj.) 3 deg F to 30 deg F, Capillary Length 5 Foot Copper, Bulb Size 1/2" x 4 3/16", Potentiometer Resistance (ohms) 135. |
| V4055A 1064 |
On-Off Fluid Power Gas Valve Actuators; Normally used with V5055A, B Valve Bodies. Low Pressure, 120 Vac 60 HZ, Opening Time = 26 sec., Includes Damper Shaft. |
| V4055A 1098 |
On-Off Fluid Power Gas Valve Actuators; Normally used with V5055A, B Valve Bodies. Low Pressure, 120 Vac 60 HZ, Opening Time = 13 sec., Includes Damper Shaft. |
| V4055D 1001 |
On-Off Fluid Power Gas Valve Actuators; On-Off Actuator includes Factory Mutual "Proff of Closure" and Underwriters Laboratories Inc. "Valve Seal Overtravel Interlock" switch. Meets Factory Mutual and Underwriters Laboratories Inc. requirements when used with V5055C valve bodies. Low Pressure, 120 Vac 60 HZ, Opening Time 26 Sec, Includes Damper Shaft |
| V4055D 1019 |
On-Off actuator includes Factory Mutual "Proof of Closure" and Underwriters Laboratories Inc. "Valve Seal Overtravel Interlock" switch. Meets Factory Mutual and Underwriters Laboratories Inc. requirements when used with V5055C valve bodies. Low Pressure, 120 Vac/60HZ |
| V4062A 1131 |
Hi-Lo-Off actuator for use with V5055B (Actuator can be used with all V5055 bodies; but best control and low fire repeatability will result with V5055B, with characterized guide.) valve bodies. Low Pressure , 120 Vac 60 HZ (Can also be used at 50 Hz; however, opening time (26 sec) will increase by 20%.), Opening Time = 13 sec., Includes Damper Shaft. |
| V48A 2334 |
Gas Valve; Pipe Size 1", Capacity (Cfh natural gas 1000 Btu/cu ft, 0.64 sp gr. p.d. 1 in. wc (m3/hr nat. gas 37.3 MJ/m3, 0.64 sp, gr. p.d. 0.25 kPa.)) cfh = 1021, M3/hr = 28.9, Electrical Ratings, Power Supply = 120V, 60 Hz, Pressure, Maximum Sustained = 1 psi |
| V5055B 1002 |
Gas Valve; Application = Low Pressure characterized guide (provides slowly increasing gs flow on opening.) Pipe Size = 1" |
|
| V5055B 1010 |
Gas Valve; Application = Low Pressure characterized guide (provides slowly increasing gs flow on opening.) Pipe Size = 1 1/4" |
|
| V5055B 1028 |
Gas Valve; Application = Low Pressure characterized guide (provides slowly increasing gs flow on opening.) Pipe Size = 1 1/2" |
|
| V5055B 1069 |
Gas Valve; Application = Low Pressure characterized guide (provides slowly increasing gs flow on opening.) Pipe Size = 2" |
|
| V5055B 1077 |
Gas Valve; Application = Low Pressure characterized guide (provides slowly increasing gs flow on opening.) Pipe Size = 2 1/2" |
|
| *** |
These Parts are no longer manufactured, Availability is subject to change |
|