fireye

Cisco Boiler Service Co., Inc.

Fireye

Flame Safeguard Controls & Accessories

Back to home page:





Flame Monitor - E100 120VAC 50/60HZ
The FIREYE FLAME-MONITOR System is a microprocessor based, burner management control system with self diagnostics, non-volatile memory and a vocabulary of 42 different messages which scroll out on the message center to provide the operator with status and failure mode information.
The FLAME-MONITOR Series is designed to provide the proper burner sequencing, ignition and flame monitoring protection on automatically ignited oil, gas and combination fuel burner. On a safety shutdown, the message center will advise the operator that the control is in "Lockout" and scroll a message indicating the cause as well as position in the sequence it occurred.
The FLAME-MONITOR uses the same wiring base as the Fireye D Series and C Series Controls and is designed to be directly interchangeable with most models without rewiring.
The FLAME-MONITOR can be used with ultraviolet, autocheck infrared, photocell, flame rod or self-check ultraviolet flame scanners by choosing the proper amplifier module.
Special Features Include: remote reset, remote display, data communications interface to retrieve current and historical burner status data from remote terminals.


M-Series Burner Controls
The FIREYE M-SERIES CONTROLS are designed for heating or automatically ignited process burners using light oil, gas or combination light oil/gas fuels (single or multiple burner installations).
The M-SERIES CONTROLS pilot and main flames, utilizing miniature UV, or Flame Rod and Photocell flame detectors. On pilot ignited burners, the main fuel valve will not be energized unless a pilot flame is proved. The control systems automatically cycles the burner on and off as required by the operating control. Manual reset is required following safety lockout.



Flame Amplifier Modules
The Fireye Flame Amplifier Modules are used in conjunction with the appropriate flame scanner to provide flame scanning capability in the Flame-Monitor system. Fiyeye offers ultraviolet amplifiers (EUV1), self check ultraviolet amplifiers (EUVS4), flame rectification amplifiers for use with flame rods and photocells (ERT1), and auto-check infrared amplifiers: E1R1 (standard model), E1R2 (high sensitivity - conult factory before use ), E1R3 (for solid fuels).
Self-checking ultra-violet scanners and amplifiers should be used in applications where the burner firing operation is continuous or where the burner is on for long periors of time (i.e. 24 hours) without cycling. The flame amplifier must be used with the appropriate flame scanners as shown below. When replacing any flame scanner or amplifier, the burner should be cycled on and off several time to ensure proper operation.
Part Number Description
EUV1 Uv Amplifier for UV1A, UV8A, UV2, 45UV3, UV90
E1R1 Infrared Amplifier for 48PT2 Scanner
E1R2 Infrared Amplifier (High Sensitivity) for 48PT2 Scanner. Consult factory before use
E1R3 Infrared Amplifier (for solid fuels) for 48PT2 Scanner.
EUVS4 Self Check UV Amplifier for 45UV5-1007, -1008, -1009
ERT1 Rectification Amplifier for 45CM1, 69ND1




Fireye E1R1, EUV1, ERT1, and EUVS4 Flame Amplifier Modules
The Fireye E1R1, EUV1, ERT1, and EUVS4 Amplifier Modules are used in conjunction with the Fireye Flame Monitor system. The moudles provide flame scanning using any of the Fireye Auto Check infrared scanners, standard ultraviolet scanners, flame rod, photocell and ultraviolet self check scanners. After scanner selection the proper amplifier module must be inserted in the Flame Monitor chassis.
Fireye Part Number Description Use With Scanner
EUV1 Standard UV Amplifier UV1A, UV8A, 45UV3
E1R1 * Autocheck Infrared Amplifier 48PT2
E1R2 Autocheck Infrared Amplifier (For Special Applications Only) Consult Factory 48PT2
ERT1 Rectification Amplifier 45CM1, 69ND1
EUVS4 Self-Checking UV Amplifier 45UV5-1007/1008/1009
E1R3 * Auto Check Infrared Amplifier 48PT2
* The E1R1 is not to be used with solid fuel applications. It is designed for oil fog rejection. The E1R3 is suitable for all fuel applications and does not contain oil fog rejection. Equipment should be tested for the proper application of this amplifier to avoid property damages or personal injury.




Scanner Selection
Fireye Part Number Description Use With Amplifier
48PT2-1003
48PT2-9003
48PT2-1007
48PT2-9007
Infrared 1/2" straigh mount 96" cable E1R1, E1R2 * and E1R3




Scanners & Applications
Part Number Description Use With Bulletin
UV1A3
UV1A6
UV2
UV8A
1/2" NPT Connector, 3 ft flex. cable
1/2" NPT Connector, 6 ft flex. cable
3/8" NPT Connector, 3 ft flex. cable
1/2" NPT 90 deg, head, 6 ft flex. cable
FLAME-MONITOR
C,D,M Series
MB, PD, PFM Kits
-
SC 102
SC 102
-
SC 102
45UV2 - 1020
45UV2 - 1122
45UV3 - 1050
UV Scanner, 1 in. NPT Mount, 60 HZ
UV Scanner, 1 in. British Threads, 50 HZ
UV Scanner, 3/4 in. Sleeve / Setscre Mt.
25RU8 Only
25RU8 Only
C, D, M - Series
SC 103
SC 103
SC 103
45UV5 - 1005

45UV5 - 1005
45UV5 - 1006

45UV5 - 1007

45UV5 - 1008

45UV5 - 1009
UV Self-Check Scanner, 1 in. NPT Threads
25VDC Shutter Drive
Same as -1005 but British threads
UV Self - Check Scanner, Use with 72DUVSI Amplifier.
1 in. NPT Threads
UV Self Check Scanner. Use with 72DUVS4 Amplifier
1 in. NPT Threads
UV Self-Check Scanner use with 72DUVSA Amp.
1 in. British Threads, 230 VAC Shutter.
UV Self-Check Scanner. Use 72DUVS4 Amp.
1 in. NPT Threads, 120 VAC Shutter
P - Series

P - Series
D - Series

Flame-Monitor
and
D - Series
with
Self - Checking
Scanner / Amp.

SC 101
48PT1 - 1003
48PT1 - 1007
48PT1 - 9003
48PT1 - 9007
48PT1 - 9007W
1/2" NPT Conn. IR Scanner, 8 ft. Shielded cable
P - Series
P - Series
P -Series
P - Series
P - Series
SC 103
SC 103
SC 103
SC 103
SC 103
48PT2 - 1003
48PT2 - 1007
48PT2 - 9003
48PT2 - 9007
48PT2 - 9007W
1/2" NPT Conn. IR Scanner, 8ft Shielded cable
1/2" NPT with 4ft Shielded cable
-1003 with 90 deg. head
-1007 with 90 deg. head
-9007 water repellant
FLAME-MONITOR
and
C & D - Series
SC 103
SC 103
SC 103
SC 103
SC 103
69ND1 - 100K
69ND1 - 100K6
69ND1 - 100K8
45CM1 - 1000
45CM1 - 100Y
Flame Rod 12 in., 1/2 in. Mount
Flame Rod 18in., 1/2in. Mount
Flame Rod 24in., 1/2in. Mount
Photocell Scanner with out filter
Photocell Scanner with Filter
FLAME MONITOR
and
C & D Series
and
MB & M - Series
SC 103
SC 103
SC 103
SC 103
SC 103



Part Number Replaced By
45AM1 - 1000
45UV2 - 1010
UV1
UV1B
UV6
45CM1
45UV2 - 1020
UV1A3, UV1A6
UV1A