Boiler Horsepower   30 40 50 60 70 80 100 125 150 200 250 300 350 400 500 600 700 750 800 900 1000 Boiler Horsepower
Boiler Model DIM. 156 205 253 304 353 402 508 625 751 1024 1276 1506 1758 2007 2506 3004 3502 3753 4005 4502 5000 Boiler Model
Lengths:
Overall
Shell
Base
Front Plate To
Front Skid Extension
Front Plate To
Center Line of Stack
Front of Base To
End of Burner (IC Only)
Front Plate To
Nozzle

A
B
C

D

E

F

G

114
81
88

24

2

17

27

136
103
107

24

2

17

34.50

139
105
109

24

2

14

38

157
123
128

24

2

13

42

144
108
110

26

2

12

41

156
120
118

26

2

15

43

182
146
149

26

2

15

43

176
136
134

28

2

13

47

199
159
158

28

2

13

47

186
143
143

30

2

21

48

215
172
170

30

2

21

48

238
190
190

34

2

18

55

264
217
217

34

2

18

55

236
187
185

36

2

19

70

275
227
226

36

2

24

70

277
228
228

36

2

27

73

287
238
233

36

2

26

60

284
235
233

36

2

 

73

301
248
251

40

2

 

73

337
275
287

49

2

 

73

364
302
314

49

2

 

73
Lengths:
Overall
Shell
Base
Front Plate To
Front Skid Extension
Front Plate To
Center Line of Stack
Front of Base To
End of Burner (IC Only)
Front Plate To
Nozzle
Widths:
Overall
Centerline To
Lagging
Water Column
Over Jacket
Base Width Outside
Base Width Inside
H
I
J
K
L
M
61
27
34
54
38
30
61
27
34
54
38
30
65
29
36
58
40
32
65
29
36
58
40
32
73
33
40
66
50
42
73
33
40
66
50
42
73
33
40
66
50
42
80
36 1/2
44
73
50 1/2
42 1/2
80
36 1/2
44
73
50 1/2
42 1/2
90
41 1/2
48
83
65 1/2
57 1/2
90
41 1/2
48
83
65 1/2
57 1/2
99
44 1/2
55
89
70 1/2
62 1/2
99
44 1/2
55
89
70 1/2
62 1/2
110
50
60
100
80
72
110
50
60
100
80
72
116
53
63
106
87
79
124
57
67
114
87
77
132
61
71
122
87
77
132
61
71
122
87
77
132
61
71
122
87
77
132
61
71
122
87
77
Widths:
Overall
Centerline To
Lagging
Water Column
Over Jacket
Base Width Outside
Base Width Inside
Heights:
Overall
Base to Stack Outlet
Base to Lagging
Height of Runner
N
O
P
Q
73
71
12
6
73
71
12
6
77
73
12
6
77
73
12
6
85
81 1/2
12
6
85
81 1/2
12
6
85
81 1/2
12
6
92
92
12
6
92
92
12
6
102
101
12
8
102
101
12
8
108
108
12
8
108
108
12
8
119
119
12
12 5/16
119
119
12
12 5/16
127
127
12
12 5/16
135
135
12
12
143
143
12
12
143
143
12
12
143
143
12
12
143
143
12
12
Connections:
FeedWater - Right/Left
Auxiliary Conn - Right/Top
Surface Blowoff - Right
Auxiliary Comm - Top
Stack Comm. O.D.

High Pressure
Steam Nozzle
Blowdown Front
Blowdown Rear

Low Pressure
Steam Nozzle
Blowdown Front
Blowdown Rear

R
S
T
U
V


W
X
Y


W
X
Y

1
1
1
1 1/2
9 7/8


2
-
1


4
-
1

1
1
1
1 1/2
9 7/8


2
-
1


4
-
1 1/4

1
1
1
1 1/2
11 7/8


2
-
1


4
-
1 1/4

1
1
1
1 1/2
11 7/8


2
-
1


4
-
1 1/4

1 1/4
1
1
1 1/2
15 7/8


3
-
1 1/4


6 *
-
1 1/4

1 1/4
1
1
1 1/2
15 7/8


3
-
1 1/4


6 *
-
1 1/4

1 1/4
1
1
2
15 7/8


4 **
-
1 1/4


6 *
-
1 1/4

1 1/4
1
1
2
17 7/8


4 **
-
1 1/4


6 *
-
1 1/4

1 1/4
1
1
2
17 7/8


4 **
-
1 1/4


6 *
-
2

2
1
1
2
19 7/8


6 **
1 1/4
1 1/4


8 *
2
2

2
1
1
2
19 7/8


6 **
1 1/4
1 1/4


8 *
2
2

2
1
1
2
23 7/8


6 **
1 1/2
1 1/2


10 *
2
2

2
1
1

23 7/8


6 **
1 1/2
1 1/2


10 *
2
2

2
1
1
2
23 7/8


6 **
1 1/2
1 1/2


12 *
2
2

2
1
1
2
23 7/8


8 **
1 1/2
1 1/2


12 *
2
2

2
1
1
2
25 7/8


8 **
1 1/2
1 1/2


12 *
2
2

2
1
1
2
25 7/8


8 **
2
2


12 *
2
2

2
1
1
2
25 7/8


8 **
2
2


12 *
2
2

2
1
1
2
25 7/8


8 **
2
2


12 *
2
2

2
1
1
2
25 7/8


8 **
2
2


12 *
2
2

2
1
1
2
25 7/8


8 **
2
2


12 *
2
2
Connections:
FeedWater - Right/Left
Auxiliary Conn - Right/Top
Surface Blowoff - Right
Auxiliary Comm - Top
Stack Comm. O.D.

High Pressure
Steam Nozzle
Blowdown Front
Blowdown Rear

Low Pressure
Steam Nozzle
Blowdown Front
Blowdown Rear
Access Openings:
Handholds
High Pressure
Low Pressure
Manway 12x16
High Pressure
Low Pressure

Z

ZZ



5
5

-
-


5
5

-
-


4
5

1
-


4
5

1
-


4
5

1
-


4
5

1
-


4
5

1
-


4
4

1
1


4
4

1
1


4
4

1
1


4
4

1
1


4
4

1
1


4
4

1
1


4
4

1
1


4
4

1
1


4
4

1
1


4
4

1
1


4
4

1
1


4
4

1
1


4
4

1
1


4
4

1
1
Access Openings:
Handholds
High Pressure
Low Pressure
Manway 12x16
High Pressure
Low Pressure
Minimum Clearances:
Tube Removal Front
Tube Removal Rear
Rear Door Swing Rear
Rear Door Swing Side

TF
TR
DR
Ds

59
59
33
62

81
81
33
62

80
80
35
66

99
99
35
66

74
74
39
74

86
86
39
74

112
112
39
74

102
102
44
85

125
125
44
85

107
107
49
94

136
136
49
94

148
148
52
99

175
175
52
99

145
145
57
110

184
184
57
110

182
182
61
117

192
192
69
129

189
189
69
129

202
202
69
129

218
218
69
129

244
244
69
129
Minimum Clearances:
Tube Removal Front
Tube Removal Rear
Rear Door Swing Rear
Rear Door Swing Side
Minimum Boiler Room Length Allowing for Door Swing And Tube Removal Dimensions BR/DW Include 3'- 0" Clearance at Front of Boiler
Front of Boiler
Rear Of Boiler
Thru Door or Window
BF
BR
DW
171
198
174
215
246
196
218
243
200
255
280
218
219
242
209
243
266
221
295
318
247
280
300
244
326
346
267
297
314
258
355
372
287
388
406
312
442
460
339
387
402
316
466
481
356
469
480
361
497
500
379
491
494
376
517
524
393
571
587
429
625
641
456
Front of Boiler
Rear Of Boiler
Thru Door or Window
Boiler Model DIM. 156 205 253 304 353 402 508 625 751 1024 1276 1506 1758 2007 2506 3004 3502 3753 4005 4502 5000 Boiler Model
Note * 150 PSIG RF Flange All dimensions are approximate and may be used for layout. Superior Boiler Works, Inc reserves the right to change dimensions due to product or job requirement.
** DS is at maximum when DR is at minimum


To Top Of Page: